NCT05317117: Evaluating the Clinical Performance and Usability of Novel Malaria RDTs in Brazil
Prospective cross-sectional diagnostic accuracy study with 1,000 patient participants and 30 lay provider/health care worker participants. The patient participant population will be recruited at clinics. At the point of care, study staff will collect capillary blood samples and conduct malaria microscopy (both the standard of care and study specific research-grade microscopy) and two index tests: the NxTek™ Malaria P.f plus Rapid Diagnostic Test (RDT) and the NxTek™ Malaria P.f/P.v RDT. Venous blood will be collected and transferred to the laboratory where the reference PCR assay and three comparator RDTs will be run. The index RDTs will also be repeated in the laboratory. All clinical management of study participants will follow the standard of care for malaria diagnosis in Brazil and will be based on the standard microscopy result. Confirmatory testing may also be conducted, such as typing and sequencing of Plasmodium genes and antigens of interest, including but not limited to HRP2, HRP3, and pLDH as well as the human inflammatory response marker CRP. The lay provider/health worker participants will include intended users of the index tests. They will be surveyed to assess index test usability through a questionnaire to assess label and packaging comprehension as well as results interpretation.
- Status
- UNKNOWN
- Sponsor
- PATH
- Conditions
- Malaria
- Therapeutic areas
- Malaria
- Enrollment
- 1030
- Sites
- 1