NCT03982472: TENS Impact Heart Rate Via Vagus Activity
Transcutaneous electric nerve stimulation (TENS) is widely used for the treatment of adhesive capsulitis, nevertheless, its potential impact on heart physiology has not been well established. The investigator explored if TENS at shoulder region affect heart rhythm and the machinery involved. Subjects were stratified into groups received sham stimulation (TENS-S) and TENS on either the right (TENS-R) or left (TENS-L) shoulder. A built-in waveform for treating adhesive capsulitis with a maximal tolerable intensity below the pain threshold was applied to subjects form a commercial TENS equipment for 5 min. The electrocardiogram (ECG) and heart rate (HR) were continuously recorded and the ECG was off-line transferred into power spectrum for analysis.
- Status
- COMPLETED
- Sponsor
- Taipei Medical University
- Conditions
- Heart Rate, Transcutaneous Electric Nerve Stimulation
- Enrollment
- 32
- Sites
- 1