NCT03750435: Non-fluoroscopy Ablation of AF/AT

Atrial fibrillation is the most common arrhythmia but can be treated by a catheter procedure where specialized wires (so-called catheters) are inserted in the left upper heart chamber. This requires crossing the wall between the right and left atrium with a long needle (a so-called transseptal puncture or TSP). This is typically done using x-ray guidance or echo to check if the needle is in the right position. The investigators developed a method to do the TSP without x-rays using a specialized needle that can be also shown as a little icon on the 3D electroanatomical mapping system (CARTO).3D mapping systems are routinely used to track the location of the catheters in cath labs worldwide, but the position of the needle was not tracked yet. The investigators seek to demonstrate that these procedures can be carried out safely, successfully and in a reproducible fashion without any radiation by taking advantage of "faking" the isolated tip of the needle as a catheter on the 3D mapping system. The results will be compared with historic procedures done by the same operator in the years 2012-2017.

Status
UNKNOWN
Sponsor
Royal Brompton & Harefield NHS Foundation Trust
Conditions
AF - Atrial Fibrillation, Atrial Tachycardia
Therapeutic areas
Atrial Fibrillation
Enrollment
25
Sites
1

Sites running this trial

Browse all clinical trials