NCT03400553: Troponin POCT in the Diagnosis of an Acute Myocardial Infarction

Thoracic pain can be caused by a life threatening disease as for instance a heart attack. Fast diagnosis and treatment is necessary for an advantageous clinical outcome. When a patient enters the emergency unit, an electrocardiogram (ECG) can diagnose a heart attack by recording the electrical activity of the patients' heart. However, an increasing number of patients with an acute myocardial infarction (AMI) are presenting without significant abnormalities on ECG In the latter group, diagnosis is dependent of elevated biochemical markers of myocardiocyte necrosis in the blood such as troponin. Generally, troponins are determined in blood and are analyzed by radiometry or at the hospital's laboratory. Time loss in the acquisition of troponin levels can occur during the workflow due to blood sampling difficulties, transport of the blood samples, processing in the laboratory, and processes inherent to the measuring assays. Roche developed a portable point-of-care (POC) device that determines troponin-T in a few minutes by using small volumes of the patient's blood with the added value that this device can be used in a pre-hospital setting which might save a significant amount of time in determining troponin levels.In this way, a faster diagnosis of AMI can be made improving patients' outcome.

Status
COMPLETED
Sponsor
Ziekenhuis Oost-Limburg
Conditions
Acute Myocardial Infarction, Troponin
Enrollment
71
Sites
1

Sites running this trial