NCT02058030: The Influence of Degree of Head Elevation on Insertion Success for ProSeal Laryngeal Mask Airway Insertion

Background - The purpose of the present study is to evaluate the success and pharyngeal trauma when 3 or 6 cm height of pillow is used for the ProSealTM laryngeal mask airway insertion Methods \- This prospective randomized, controlled study included 80 adult patients . In the 3 cm (n=40) or 6 cm group (n=40), the PLMA was inserted while the head is placed on the 3 cm or 6 cm height of pillow. The success rate at first and second attempt, insertion time, blood staining on cuff, sore throat and hoarseness were assessed.

Status
COMPLETED
Sponsor
National Medical Center, Seoul
Conditions
Anesthesia
Enrollment
80
Sites
1

Sites running this trial

Browse all clinical trials