NCT01625975: Retrospective Eight Plate Study
Understanding bone growth and achieving bone deformity corrections re-mains one of the oldest challenges in paediatric orthopaedics. The purpose of this study is to investigate the clinical and biomechanical effects of implants for growth modulation in pediatric patients undergoing correction of leg length or deformities of the knee. The primary aim of the study is to assess outcome after growth modulation using the Eight plate (Orthofix) at the time of implant removal with regard to any Adverse Events (AE) related to the growth plates or implants under investigation. The secondary aims are to assess if the planned correction was achieved and if the achieved correction was maintained after implant removal. Furthermore, secondary aims include investigation of the number and type of revision surgeries, the proportions of any other local AE as well as any influencing factors for growth modulation.
- Status
- COMPLETED
- Sponsor
- AO Clinical Investigation and Publishing Documentation
- Conditions
- Leg Length Discrepancy, Varus/Valgus Deformities of the Knee
- Therapeutic areas
- Leg Length Inequality
- Enrollment
- 138
- Sites
- 7
Sites running this trial
- Inselspital Bern, Bern, Canton of Bern, Switzerland
- Klinikum Stuttgart, Stuttgart, Stuttgart, Germany
- Hôpital des enfants, Geneva, Switzerland
- Kinderchirurgische Klinik, Karlsruhe, Germany
- Sancheti Institute for Orthopaedics and Rehabilitation, Pune, Maharashtra, India
- Universitätskinderspital Zürich, Zurich, Switzerland
- Guy Hilton Research Centre ISTM, Keele University, Stoke-on-Trent, United Kingdom