NCT01007487: Plastic Wound Retractors and Bacterial Translocation in Abdominal Surgery

Hypothesis: Plastic wound retractors reduce passage of bacteria from the abdomen to the surgical incision site in abdominal surgery Currently, plastic wound retractors are used in abdominal surgery to facilitate access to the abdominal cavity. This study aims to establish whether they also prevent bacteria crossing from the abdominal cavity to the surgical incision site. Patients undergoing abdominal surgery in which a plastic wound retractor (Alexis®)is used are eligible for inclusion in the study. Swabs are taken from the inside and the outside of the plastic wound retractor prior to removing the retractor from the abdomen. The bacterial flora from swabs taken inside and outside the plastic wound protector are then compared to see if there is any difference between inside and outside the retractor. Bacteria are classified as 'enteric'(i.e. from the gastrointestinal tract) or 'skin' bacteria, depending on their usual location. The study aims to establish whether a plastic wound retractor (Alexis®) reduces translocation of enteric bacteria to the surgical incision site.

Status
COMPLETED
Sponsor
St Vincent's University Hospital, Ireland
Conditions
Abdominal Surgery, Bacterial Translocation, Surgical Site Infection, Wound Infection
Therapeutic areas
Surgical Wound Infection, Wound Infection
Enrollment
250
Sites
2

Sites running this trial

Browse all clinical trials